| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| A command injection vulnerability exists in the eScan Web Management Console version 5.5-2. The application fails to properly sanitize the 'pass' parameter when processing login requests to login.php, allowing an authenticated attacker with a valid username to inject arbitrary commands via a specially crafted password value. Successful exploitation results in remote code execution. Privilege escalation to root is possible by abusing the runasroot utility with mwconf-level privileges. |
| A remote code execution vulnerability exists in HybridAuth versions 2.0.9 through 2.2.2 due to insecure use of the install.php installation script. The script remains accessible after deployment and fails to sanitize input before writing to the application’s config.php file. An unauthenticated attacker can inject arbitrary PHP code into config.php, which is later executed when the file is loaded. This allows attackers to achieve remote code execution on the server. Exploitation of this issue will overwrite the existing configuration, rendering the application non-functional. |
| The affected product is vulnerable to an attacker being able to use commands without providing a password which may allow an attacker to leak information. |
| In the Airoha Bluetooth audio SDK, there is a possible permission bypass that allows access critical data of RACE protocol through Bluetooth LE GATT service. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| A low privileged remote attacker may modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS. |
| When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks. |
| Improper control of framework service permissions with possibility of some sensitive device information leakage. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leading to full system compromise. |
| Missing Authentication & Authorization in Web-API in Mobatime AMX MTAPI v6 on IIS allows adversaries to unrestricted access via the network. The vulnerability is fixed in Version 1.5. |
| A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced. |
| A unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via CAN. |
| Missing Authentication - User & System Configuration |
| An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485). |