| Due to improper input validation, a buffer overflow vulnerability is present in
Zigbee EZSP Host Applications. If the buffer overflows, stack corruption is possible. In certain
conditions, this could lead to arbitrary code execution. Access to a network key is required to exploit this vulnerability. |
| A SQL injection vulnerability has been identified in DobryCMS. Improper neutralization of input provided by user into language functionality allows for SQL Injection attacks.
This issue affects older branches of this software. |
| A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." |
| A vulnerability was identified in INSTAR 2K+ and 4K 3.11.1 Build 1124. This affects the function base64_decode of the component fcgi_server. The manipulation of the argument Authorization leads to buffer overflow. It is possible to initiate the attack remotely. |
| Telenium Online Web Application is vulnerable due to a Perl script that
is called to load the login page. Due to improper input validation, an
attacker can inject arbitrary Perl code through a crafted HTTP request,
leading to remote code execution on the server. |
| Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code. |
| Official Document Management System developed by 2100 Technology has an Authentication Bypass vulnerability, allowing unauthenticated remote attackers to obtain any user's connection token and use it to log into the system as that user. |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |
| Amazon EMR Secret Agent creates a keytab file containing Kerberos credentials. This file is stored in the /tmp/ directory. A user with access to this directory and another account can potentially decrypt the keys and escalate to higher privileges.
Users are advised to upgrade to Amazon EMR version 7.5 or higher. For Amazon EMR releases between 6.10 and 7.4, we strongly recommend that you run the bootstrap script and RPM files with the fix provided in the location below. |
| Use of Insufficiently Random Values vulnerability in form-data allows HTTP Parameter Pollution (HPP). This vulnerability is associated with program files lib/form_data.Js.
This issue affects form-data: < 2.5.4, 3.0.0 - 3.0.3, 4.0.0 - 4.0.3. |
| Tigo Energy's Cloud Connect Advanced (CCA) device contains hard-coded credentials that allow unauthorized users to gain administrative access. This vulnerability enables attackers to escalate privileges and take full control of the device, potentially modifying system settings, disrupting solar energy production, and interfering with safety mechanisms. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. The system employs a hard-coded secret key to sign JSON Web Tokens (JWT) used for authentication. This insecure implementation allows an unauthenticated attacker to forge valid tokens, thereby bypassing authentication controls and impersonating any user. Exploitation of this vulnerability can result in complete system compromise, enabling unauthorized access, data theft, and full administrative control over the affected device. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |
| Input from search query parameter in GOV CMS is not sanitized properly, leading to a Blind SQL injection vulnerability, which might be exploited by an unauthenticated remote attacker.
Versions 4.0 and above are not affected. |
| A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. |
| The SFT developed by Digiwin has a SQL Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary SQL commands to read, modify, and delete database contents. |
| A certificate verification error in wolfSSL when building with the WOLFSSL_SYS_CA_CERTS and WOLFSSL_APPLE_NATIVE_CERT_VALIDATION options results in the wolfSSL
client failing to properly verify the server certificate's domain name,
allowing any certificate issued by a trusted CA to be accepted regardless of the hostname. |
| Information disclosure and exposure of authentication FTP credentials over the debug port 1604 in the MINOVA TTA service. This allows unauthenticated remote access to an active FTP account containing sensitive internal data and import structures. In environments where this FTP server is part of automated business processes (e.g. EDI or data integration), this could lead to data manipulation, extraction, or abuse. Debug ports 1602, 1603 and 1636 also expose service architecture information and system activity logs |