| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A deserialization vulnerability exists in Volcengine's verl 3.0.0, specifically in the scripts/model_merger.py script when using the "fsdp" backend. The script calls torch.load() with weights_only=False on user-supplied .pt files, allowing attackers to execute arbitrary code if a maliciously crafted model file is loaded. An attacker can exploit this by convincing a victim to download and place a malicious model file in a local directory with a specific filename pattern. This vulnerability may lead to arbitrary code execution with the privileges of the user running the script. |
| Network access can be used to execute arbitrary code with elevated privileges.
This
issue affects FLXEON 9.3.4 and older. |
| An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
Affected Products:
EdgeMAX EdgeSwitch (Version 1.11.0 and earlier)
Mitigation:
Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later. |
| An e-mail flooding vulnerability in StrangeBee TheHive 5.2.0 before 5.2.16, 5.3.0 before 5.3.11, 5.4.0 before 5.4.10, and 5.5.0 before 5.5.1 allows unauthenticated remote attackers to use the password reset feature without limits. This can lead to several consequences, including mailbox storage exhaustion for targeted users, reputation damage to the SMTP server, potentially causing it to be blacklisted, and overload of the SMTP server's outbound mail queue. |
| An Improper Input Validation in UISP Application could allow a Command Injection by a malicious actor with High Privileges and local access. |
| Sercomm Router Etisalat Model S3- AC2100 is affected by Incorrect Access Control via the diagnostic utility in the router dashboard. |
| Large content vulnerabilities are present in ASPECT exposing a device to disk overutilization on a system if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| A vulnerability was found in Bohua NetDragon Firewall 1.0 and classified as critical. This issue affects some unknown processing of the file /systemstatus/ip_status.php. The manipulation of the argument subnet leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. |
| The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance. |
| A denial of service (DoS) vulnerability has been identified in the JavaScript library microlight version 0.0.7. This library, used for syntax highlighting, does not limit the size of textual content it processes in HTML elements with the microlight class. When excessively large content (e.g., 100 million characters) is processed, the reset function in microlight.js consumes excessive memory and CPU resources, causing browser crashes or unresponsiveness. An attacker can exploit this vulnerability by tricking a user into visiting a malicious web page containing a microlight element with large content, resulting in a denial of service. NOTE: this is disputed by multiple parties because a large amount of memory and CPU resources is expected to be needed for content of that size. |
| A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages. |
| Databricks JDBC Driver 2.x before 2.6.40 could potentially allow remote code execution (RCE) by triggering a JNDI injection via a JDBC URL parameter. The vulnerability is rooted in the improper handling of the krbJAASFile parameter. An attacker could potentially exploit this vulnerability to achieve Remote Code Execution in the context of the driver by tricking a victim into using a crafted connection URL that uses the property krbJAASFile. |
| Allocation of resources without limits or throttling issue exists in HMI ViewJet C-more series and HMI GC-A2 series, which may allow a remote unauthenticated attacker to cause a denial-of-service (DoS) condition. |
| A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was detected in sequa-ai sequa-mcp up to 1.0.13. This affects the function redirectToAuthorization of the file src/helpers/node-oauth-client-provider.ts of the component OAuth Server Discovery. Performing manipulation results in os command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used. Upgrading to version 1.0.14 is able to mitigate this issue. The patch is named e569815854166db5f71c2e722408f8957fb9e804. It is recommended to upgrade the affected component. The vendor explains: "We only promote that mcp server with our own URLs that have a valid response, but yes if someone would use it with a non sequa url, this is a valid attack vector. We have released a new version (1.0.14) that fixes this and validates that only URLs can be opened." |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability. |
| Hackney fails to properly release HTTP connections to the pool after handling 307 Temporary Redirect responses. Remote attackers can exploit this to exhaust connection pools, causing denial of service in applications using the library.
Fix for this issue has been included in 1.24.0 release. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0. |
| A vulnerability affecting HPE Networking Instant On Access Points has been identified where a device processing a specially crafted packet could enter a non-responsive state, in some cases requiring a hard reset to re-establish services. A malicious actor could leverage this vulnerability to conduct a Denial-of-Service attack on a target network. |
| The affected device expose a network service called "rftest" that is vulnerable to unauthenticated command injection on ports TCP/8888, TCP/8889, and TCP/8890. By successfully exploiting this flaw, remote unauthenticated attacker can gain arbitrary command execution on the device with elevated privileges.This issue affects Archer C4500X: through 1_1.1.6. |