| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| Buffer overflow vulnerability in Immunity Debugger affecting version 1.85, its exploitation could allow a local attacker to execute arbitrary code, due to the lack of proper boundary checking. |
| Improper buffer restrictions in the firmware for the TDX Module may allow an escalation of privilege. System software adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (low) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. |
| The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. Prior to 1.61.2 and 2.1.1, the operation limits plugin uses unsigned 32-bit integers to track limit counters (e.g. for a query's height). If a counter exceeded the maximum value for this data type (4,294,967,295), it wrapped around to 0, unintentionally allowing queries to bypass configured thresholds. This could occur for large queries if the payload limit were sufficiently increased, but could also occur for small queries with deeply nested and reused named fragments. This has been remediated in apollo-router versions 1.61.2 and 2.1.1. |
| Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki Core - Feed Utils allows WebView Injection.This issue affects Mediawiki Core - Feed Utils: from 1.39 through 1.43. |
| Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Confirm Account Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Confirm Account Extension: from 1.39 through 1.43. |
| Improper buffer restrictions in some Intel(R) System Security Report and System Resources Defense firmware may allow a privileged user to potentially enable escalation of privilege via local access. |
| Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Version Compare Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Version Compare Extension: from 1.39 through 1.43. |
| Improper buffer restrictions in some Intel(R) System Security Report and System Resources Defense firmware may allow a privileged user to potentially enable escalation of privilege via local access. |
| A vulnerability was determined in appneta tcpreplay up to 4.5.2-beta2. The impacted element is the function untrunc_packet of the file src/tcpedit/edit_packet.c of the component tcprewrite. Executing manipulation can lead to use after free. It is possible to launch the attack on the local host. The exploit has been publicly disclosed and may be utilized. This patch is called 73008f261f1cdf7a1087dc8759115242696d35da. Applying a patch is advised to resolve this issue. |
| A vulnerability was found in MicroDicom DICOM Viewer 2025.1 Build 3321. It has been classified as critical. Affected is an unknown function of the file mDicom.exe. The manipulation leads to memory corruption. The attack needs to be approached locally. It is recommended to upgrade the affected component. The vendor quickly confirmed the existence of the vulnerability and fixed it in the latest beta. |
| A vulnerability was found in PX4 PX4-Autopilot up to 1.15.4. This issue affects the function MavlinkReceiver::handle_message_serial_control of the file src/modules/mavlink/mavlink_receiver.cpp of the component Mavlink Shell Closing Handler. The manipulation of the argument _mavlink_shell leads to use after free. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. The identifier of the patch is 4395d4f00c49b888f030f5b43e2a779f1fa78708. It is recommended to apply a patch to fix this issue. |
| Misinterpretation of Input vulnerability in OpenText™ Service Management Automation X (SMAX), OpenText™ Asset Management X (AMX), and OpenText™ Hybrid Cloud Management X (HCMX) products. The vulnerability could allow Input data manipulation.This issue affects Service Management Automation X (SMAX) versions: 2020.05, 2020.08, 2020.11, 2021.02, 2021.05, 2021.08, 2021.11, 2022.05, 2022.11, 2023.05; Asset Management X (AMX) versions: 2021.08, 2021.11, 2022.05, 2022.11, 2023.05; and Hybrid Cloud Management X (HCMX) versions: 2020.05, 2020.08, 2020.11, 2021.02, 2021.05, 2021.08, 2021.11, 2022.05, 2022.11, 2023.05.
|
| A firmware bug which may lead to misinterpretation of data in the AMC2-4WCF and AMC2-2WCF allowing an adversary to grant access to the last authorized user. |
| Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| A vulnerability was found in D-Link DIR-513 up to 20190831. It has been declared as critical. This vulnerability affects the function formSetWanDhcpplus of the file /goform/formSetWanDhcpplus. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. This vulnerability only affects products that are no longer supported by the maintainer. |
| A vulnerability was found in Netgear R6900 1.0.1.26_1.0.20. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file upgrade_check.cgi of the component HTTP Header Handler. The manipulation of the argument Content-Length leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to
unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious
user, having physical access, sets the radio to the factory default mode. |
| A vulnerability was found in AcademySoftwareFoundation OpenColorIO up to 2.5.0. This issue affects the function ConvertToRegularExpression of the file src/OpenColorIO/FileRules.cpp. Performing a manipulation results in out-of-bounds read. The attack needs to be approached locally. The exploit has been made public and could be used. The patch is named ebdbb75123c9d5f4643e041314e2bc988a13f20d. To fix this issue, it is recommended to deploy a patch. The fix was added to the 2.5.1 milestone. |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates.
This could allow an unauthenticated remote attacker to crash the network service. |