| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Go may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Go to version 4.0 or later. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Java may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Java to version 4.0.0 or later. |
| Missing cryptographic key commitment in the AWS SDK for Ruby may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for Ruby to version 1.208.0 or later. |
| Missing cryptographic key commitment in the AWS SDK for PHP may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for PHP to version 3.368.0 or later |
| Missing cryptographic key commitment in the AWS SDK for C++ may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for C++ to version 1.11.712 or later |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for .NET may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for .NET to version 3.2.0 or later. |
| A vulnerability has been found in running-elephant Datart up to 1.0.0-rc3. Affected by this issue is the function getTokensecret of the file datart/security/src/main/java/datart/security/util/AESUtil.java of the component API. The manipulation leads to use of hard-coded cryptographic key
. The attack is possible to be carried out remotely. The attack is considered to have high complexity. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| A vulnerability in the SageMaker Workflow component of aws/sagemaker-python-sdk allows for the possibility of MD5 hash collisions in all versions. This can lead to workflows being inadvertently replaced due to the reuse of results from different configurations that produce the same MD5 hash. This issue can cause integrity problems within the pipeline, potentially leading to erroneous processing outcomes. |
| itech iLabClient 3.7.1 relies on the hard-coded YngAYdgAE/kKZYu2F2wm6w== key (found in iLabClient.jar) for local users to read or write to the database. |
| Web installer integrity check used weak hash algorithm. The following products are affected: Acronis Cyber Protect 16 (Windows) before build 39169. |
| openwrt/asu is an image on demand server for OpenWrt based distributions. The request hashing mechanism truncates SHA-256 hashes to only 12 characters. This significantly reduces entropy, making it feasible for an attacker to generate collisions. By exploiting this, a previously built malicious image can be served in place of a legitimate one, allowing the attacker to "poison" the artifact cache and deliver compromised images to unsuspecting users. This can be combined with other attacks, such as a command injection in Imagebuilder that allows malicious users to inject arbitrary commands into the build process, resulting in the production of malicious firmware images signed with the legitimate build key. This has been patched with 920c8a1. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.
This could allow an attacker to guess or decrypt the password from the cyphertext. |
| A vulnerability was found in Satellite. When running a remote execution job on a host, the host's SSH key is not being checked. When the key changes, the Satellite still connects it because it uses "-o StrictHostKeyChecking=no". This flaw can lead to a man-in-the-middle attack (MITM), denial of service, leaking of secrets the remote execution job contains, or other issues that may arise from the attacker's ability to forge an SSH key. This issue does not directly allow unauthorized remote execution on the Satellite, although it can leak secrets that may lead to it. |
| Pheonix App is a Python application designed to streamline various tasks, from managing files to playing mini-games. The issue is that the map of encoding/decoding languages are visible in code. The Problem was patched in 0.2.4. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS).
This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. |
| An issue was discovered on Swissphone DiCal-RED 4009 devices. An attacker with access to the file /etc/deviceconfig may recover the administrative device password via password-cracking methods, because unsalted MD5 is used. |
| php-censor v2.1.4 and fixed in v.2.1.5 was discovered to utilize a weak hashing algorithm for its remember_key value. This allows attackers to bruteforce to bruteforce the remember_key value to gain access to accounts that have checked "remember me" when logging in. |
|
A hard-coded AES key vulnerability was reported in the Motorola GuideMe application, along with a lack of URI sanitation, could allow for a local attacker to read arbitrary files.
|
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.
A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network. |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |