| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in Moxa EDR-810 Industrial Secure Router. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access configuration and log files (PRIVILEGE ESCALATION). |
| tpm2-tools versions before 1.1.1 are vulnerable to a password leak due to transmitting password in plaintext from client to server when generating HMAC. |
| Apache OpenMeetings before 3.1.2 is vulnerable to Remote Code Execution via RMI deserialization attack. |
| Apache Brooklyn uses the SnakeYAML library for parsing YAML inputs. SnakeYAML allows the use of YAML tags to indicate that SnakeYAML should unmarshal data to a Java type. In the default configuration in Brooklyn before 0.10.0, SnakeYAML will allow unmarshalling to any Java type available on the classpath. This could provide an authenticated user with a means to cause the JVM running Brooklyn to load and run Java code without detection by Brooklyn. Such code would have the privileges of the Java process running Brooklyn, including the ability to open files and network connections, and execute system commands. There is known to be a proof-of-concept exploit using this vulnerability. |
| PostgreSQL versions before 9.2.22, 9.3.18, 9.4.13, 9.5.8 and 9.6.4 are vulnerable to authorization flaw allowing remote authenticated attackers to retrieve passwords from the user mappings defined by the foreign server owners without actually having the privileges to do so. |
| A flaw was found in instack-undercloud 7.2.0 as packaged in Red Hat OpenStack Platform Pike, 6.1.0 as packaged in Red Hat OpenStack Platform Oacta, 5.3.0 as packaged in Red Hat OpenStack Newton, where pre-install and security policy scripts used insecure temporary files. A local user could exploit this flaw to conduct a symbolic-link attack, allowing them to overwrite the contents of arbitrary files. |
| A flaw was found in the way Ansible (2.3.x before 2.3.3, and 2.4.x before 2.4.1) passed certain parameters to the jenkins_plugin module. Remote attackers could use this flaw to expose sensitive information from a remote host's logs. This flaw was fixed by not allowing passwords to be specified in the "params" argument, and noting this in the module documentation. |
| An information disclosure vulnerability in Fortinet FortiWeb 5.8.2 and below versions allows logged-in admin user to view SNMPv3 user password in cleartext in webui via the HTML source code. |
| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
| A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. |
| A Password in Configuration File issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The password in configuration file vulnerability was identified, which could lead to a malicious user assuming the identity of a privileged user and gaining access to sensitive information. |
| In the cron package through 3.0pl1-128 on Debian, and through 3.0pl1-128ubuntu2 on Ubuntu, the postinst maintainer script allows for group-crontab-to-root privilege escalation via symlink attacks against unsafe usage of the chown and chmod programs. |
| register.ghp in EFS Software Easy Chat Server versions 2.0 to 3.1 allows remote attackers to discover passwords by sending the username parameter in conjunction with an empty password parameter, and reading the HTML source code of the response. |
| Password exposure in Cognito Software Moneyworks 8.0.3 and earlier allows attackers to gain administrator access to all data, because verbose logging writes the administrator password to a world-readable file. |
| Csrf.cs in NancyFX Nancy before 1.4.4 and 2.x before 2.0-dangermouse has Remote Code Execution via Deserialization of JSON data in a CSRF Cookie. |
| Apache Camel's Jackson and JacksonXML unmarshalling operation are vulnerable to Remote Code Execution attacks. |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files. |
| Remote Code Execution is possible in Code42 CrashPlan 5.4.x via the org.apache.commons.ssl.rmi.DateRMI Java class, because (upon instantiation) it creates an RMI server that listens on a TCP port and deserializes objects sent by TCP clients. |
| An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of characters. NOTE: the vendor reports that the 12-character limit provides "a very high security standard." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session. |