| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An escalation of privilege vulnerability in ASPECT could provide an attacker root access to a server when logged in as a "non" root ASPECT user. This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| An attacker who successfully exploited these vulnerabilities could cause the robot to stop.
A vulnerability exists in the PROFINET stack included in the RobotWare versions listed below.
This vulnerability arises under specific condition when specially crafted message is processed by the system.
Below are reported vulnerabilities in the Robot Ware versions.
* IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 |
| Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE.
When the REST interface is enabled by the user, and an attacker gains access to
the control network, and user/password broker authentication is enabled, and
CVE-2025-6074 is exploited, the attacker can overflow the buffer for username or
password.
This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016. |
| Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2. |
| Predictable filename vulnerabilities in ASPECT may expose sensitive information to a potential attacker if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Stored Absolute Path Traversal vulnerabilities in ASPECT could expose sensitive data
if administrator credentials become compromised.
This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Sensitive device logger information in ASPECT may be exposed if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Log injection vulnerabilities in ASPECT provide attacker access to inject malicious browser scripts if administrator credentials become compromised.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Relative Path Traversal vulnerabilities in ASPECT allow access to file resources if session administrator credentials become compromised.
This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| An Unchecked Loop Condition in ASPECT provides an attacker the ability to maliciously consume system resources if session administrator credentials become compromised
This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| 2nd Order SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if administrator credentials become compromised.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| SSRF Server Side Request Forgery vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Improper Input Validation vulnerability in ABB 800xA Base.
An attacker who successfully exploited this
vulnerability could cause services to crash by sending specifically crafted messages.
This issue affects 800xA Base: from 6.0.0 through 6.1.1-2. |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. |
| An attacker could exploit the vulnerability by
injecting garbage data or specially crafted data. Depending on the data injected each process might be
affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing
the product to store wrong information or act on wrong data or display wrong information.
This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
For an attack to be successful, the attacker must have local access to a node in the system and be able to
start a specially crafted application that disrupts the communication.
An attacker who successfully exploited the vulnerability would be able to manipulate the data in such
way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300
and AdvaBuild to crash. |
| AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the
command queue can use it to launch an attack by running any executable on the AdvaBuild node. The
executables that can be run are not limited to AdvaBuild specific executables.
Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. |
| An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible.
The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system.
Below are reported vulnerabilities in the Robot Ware versions.
* IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07
* OmniCore- RobotWare 7 < 7.14 |