| An unauthenticated attacker with access to the local network of the
medical office can query an unprotected Fast Healthcare Interoperability
Resources (FHIR) API to get access to sensitive electronic health
records (EHR). |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| The affected product is vulnerable to an attacker being able to use commands without providing a password which may allow an attacker to leak information. |
| Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| Missing Authentication - User & System Configuration |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| A low-privileged local attacker can exploit improper permissions on nssm.exe to escalate their privileges and gain administrative access. |
| An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data. |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. |
| The database for the web application is exposed without authentication, allowing an unauthenticated remote attacker to gain unauthorized access and potentially compromise it. |
| The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application. |
| Due to missing authentication, SAP HANA 2.0 (hdbrss) allows an unauthenticated attacker to call a remote-enabled function that will enable them to view information. As a result, it has a low impact on the confidentiality but no impact on the integrity and availability of the system. |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| The CE Phoenix eCommerce platform, starting in version 1.0.9.7 and prior to version 1.1.0.3, allowed logged-in users to delete their accounts without requiring password re-authentication. An attacker with temporary access to an authenticated session (e.g., on a shared/public machine) could permanently delete the user’s account without knowledge of the password. This bypass of re-authentication puts users at risk of account loss and data disruption. Version 1.1.0.3 contains a patch for the issue. |
| An unauthenticated remote attacker can run arbitrary commands on the affected devices with high privileges because the authentication for the Node_RED server is not configured by default. |
| It is possible to bypass the administrator login screen on SolaX Cloud. An attacker could use parameter tampering to bypass the login screen and gain limited access to the system. |